Skip to main content

Table 3 Analytical parameters for the analysis of Tenofovir by the purposed spectrofluorimetric, first derivative spectrophotometric, and HPLC methods

From: Novel approaches for determination of antiretroviral reverse transcriptase inhibitor agent in commercial dosage forms by using spectrofluorimetric, first derivative spectrophotometric, and HPLC methods

Parameter

Method I

Method II

Method III

Concentration range (μg/mL)

4.72–15.75

10.0–28.0

10.00–100.00

Slope (a)

39.002

0.9827

0.1398

Intercept (b)

158.85

0.0073

− 0.0387

Correlation coefficient (r)

0.9997

0.9998

0.9995

Determination coefficient (r2)

0.9994

0.9996

0.9990

Standard deviation of the slope (Sa)

1.64

1.00

0.0016

Standard deviation of the intercept (Sb)

17.85

2.79

0.0982

Limit of detection (LOD) (μg/mL)

1.51

1.31

2.32

Limit of quantitation (LOQ) (μg/mL)

4.58

4.53

7.02