Table 3 Validation parameters results for determination of perindopril and indapamide

From: Development of new stability indicating UPLC-UV method for the extraction and quantification of perindopril and indapamide from human plasma

Analyte

Nominal value (μg/mL)

Intra day

Inter day

Found concentration (μg/mL)

Precision (RSD %)

Accuracy (%)

Found concentration (ng/mL)

Precision (RSD %)

Accuracy (%)

Perindopril

1.5

1.46 ± 0.28

8.34

97.45

1.48 ± 0.65

6.48

97.12

7

7.16 ± 0.83

4.66

101.58

7.24 ± 2.51

3.51

101.2

25

25.12 ± 2.73

2.4

98.6

24.68 ± 1.54

1.08

98.05

Indapamide

0.45

0.39 ± 0.16

12.5

95.16

0.41 ± 1.23

11.12

94.56

2.5

2.48 ± 0.79

5.36

100.4

2.49 ± 0.64

3.05

99.2

12

11.22 ± 1.68

4.8

98.7

11.56 ± 3.5

3.61

97.92