- Research
- Open access
- Published:
Estimation of isoniazid by digital image colorimetry: an integration of green chemistry and smartphone technology
Future Journal of Pharmaceutical Sciences volume 10, Article number: 128 (2024)
Abstract
Background
This study proposes a simple digital image colorimetric method using a smartphone for the quantitative analysis of isoniazid in pharmaceutical medications. The analytical methodology employed in this study involved the utilization of the reaction between isoniazid and FC reagent under alkaline conditions. The chemical reaction led to the creation of a complex with a blue-gray color, exhibiting a peak absorption at a wavelength of 760 nm. An Android application was employed to perform a smartphone-based determination based on separating the captured color into different color channels such as red, blue, green, etc. The experimental procedure involved the utilization of three smartphones for the determination, which was subsequently followed by a comparative analysis of the results obtained from these devices using spectrophotometric measurements.
Results
The B channel had the highest level of optimization in terms of analytical parameters. The limits of detection (LOD) were 0.586, 2.478, and 1.396 µg/ml for S1, S2, and S3, respectively, and for the spectrophotometer, it was found to be 0.416 µg/ml. Similarly, LOQs were determined as 1.673, 7.511, 4.232, and 1.302 µg/ml. A %RSD of 1.3 for precision and an LOD of 0.013 g dm−3 were obtained for the spectroscopic method. The % recovery in the accuracy study was found to be 99.69, 101.804, 109.28, and 100.13 for S1, S2, S3, and spectrophotometer, respectively.
Conclusion
The colorimetric results from smartphone application are similar to those from spectrophotometric analyses.
Background
Pharmaceutical analysis involves qualitative and quantitative determination of analytes and is also useful for the separation and purification of compounds from the mixture. The scientific discipline known as spectroscopy is concerned with the investigation of the relationship that exists between electromagnetic radiation and all kinds of materials. In addition to being the most effective instrument now accessible for the investigation of chemical structure, it is also utilized in the examination of a broad variety of substances [1]. Different spectroscopic [2,3,4,5,6,7], electrochemical [8,9,10], and chromatographic [11,12,13,14] methods have been developed to date for the estimation of isoniazid, but there is no method till date based on digital image colorimetry that is precise, portable, and easy to use.
UV–visible spectroscopy
Electromagnetic radiation in the wavelength range of 180–400 nm is considered as the UV region, whereas 400–800 nm is the visible region. This UV–vis wavelength of light is generally absorbed by a wide range of organic molecules and causes energy transitions at the electronic level. Various transitions, such as σ to σ*, π to π*, n to σ*, and σ to π* can take place in a molecule on the absorption of radiation. Chromophore is the moiety in which these electronic transitions occur and is responsible for the color of the compound. If the molecule doesn’t have a chromophore moiety, derivatization can be done to convert it into a UV–vis active form; so that it can absorb radiation and undergo electronic transitions. These techniques include complexation, enzymatic reactions, diazotization, etc. A similar occurrence arises when sample preconcentration is employed by any separation or extraction technique [15].
In recent times, there have been significant advancements in UV–vis spectrophotometers. These advancements aim to enhance sensitivity, precision, and accuracy, while also reducing costs and analysis time. Nanodrop UV–visible spectrophotometers and microplate spectrophotometer are the best advancements found in recent times, which can utilize a very small volume of sample and also analyze large number of samples at a time, thus supporting the principles of Green Analytical Chemistry. Portable colorimeters and spectrophotometers are also available these days which can promote in situ analysis.
According to Beer–Lambert’s law, absorbance is directly proportional to concentration within a concentration range. It is expressed as,
Here, A represents absorbance or optical density, and a refers to the absorptivity or extinction coefficient. The path length b of the radiation passing through the sample is measured in centimeters. The concentration of solute in the solution c is an important factor to consider. Both b and a remain constant, indicating that a is proportional to c.
The selection of a solvent that is transparent to the wavelength selected for the study must be considered while preparing the solution. λmax is considered as a qualitative parameter for the analyte under study. Even though UV–visible spectrophotometric studies are more advantageous than other analytical methods, there are several drawbacks, such as the maintenance of the laboratory, the training of personnel, power consumption, etc. So there is a need for a simple colorimetric approach which is simple, economic, portable, and rapid without compromising its analytical performance [16].
Digital image colorimetry (DIC)
DIC is an innovative colorimetric method that uses the red, green, and blue (RGB) channels of photographs of a colored analyte solution, which are taken by digital cameras, webcams, hand scanners, or smartphone cameras. The numbers are 13 and 14. Smartphones are optimal devices for capturing images in this context due to their exceptional photographic capabilities, advanced software, and convenient mobility for image processing [3]. The advent of smartphone technology has revolutionized several scientific disciplines, including chemistry, by offering groundbreaking opportunities and applications. Smartphones play a crucial role as detecting devices in the advancement of new analytical techniques. Smartphones and digital cameras are used as digital imaging systems that rely on colorimetry. However, they may also be employed in fluorescence, chemiluminescence, and electrochemical approaches. The affordability, widespread availability, and user-friendly nature of smartphones have led to their use as instruments for the advancement of innovative analytical techniques in several fields, such as environmental monitoring, food analysis, and particularly biomedical and health tracking analysis [17].
Several applications were developed for colorimetric determination of compounds using smartphones. The choice of app for the present study was Photometrix, which has an extension version of Photometrix Pro® and Photometrix UVC®. It analyzes the digital images captured by the smartphone camera and decomposes the color of the picture into different channels such as R (Red), G (Green), B (Blue), H (Hue), S (Saturation), V (Value or brightness), L (Lightness), and I (Intensity) which can be constructed as the RGB model, HSL model, HSV model, and HIS model. The application is feasible with both univariate and multivariate analysis. Each sample will record the values obtained for every channel in the image. The Photometrix app has another advantage of obtaining a calibration curve for a series of concentrations kept for study, which makes it more feasible [18].
Principles of digital image colorimetry (DIC)
Key elements of digital image colorimetry systems encompass various aspects such as color spaces, tools for picture capture, illumination, applications for color quantification, and DIC applications. First, color spaces are carefully selected to meet different requirements, enhancing the precision of the analysis results. Here is a comprehensive overview of the commonly used color spaces.
Advancements in digital photography have made it more affordable and convenient to capture high-resolution images using a smartphone's digital camera. The potential for creating fast and affordable digital image correlation (DIC) on smartphones for various assessments, such as drugs, natural compounds, biomolecules, toxins, antibiotics, heavy metals, microbes, etc., is driven by the popularity of digital pictures.
Several advancements in digital image colorimetry took place because of computational capabilities and widespread usage of mobile phones. Smartphone-based studies were also applied to microfluidics and paper-based devices in several tests. These technologies are utilized for point-of-care testing in the healthcare sector and other businesses, also known as point-of-need testing. Hence, the digital image correlation (DIC) on smartphones is unambiguously scored as a 5 [19].
Photometrix pro
Due to more advancements in image acquisition and processing techniques in smartphones and their easy availability, several applications were developed for studying digital images. Digital images have revolutionized various applications that were once limited to specialized equipment like colorimeters, spectrophotometers, and fluorometers. Their effectiveness is well-documented. This function represents the distribution of luminous energy, in which some amount of energy is absorbed, some is transmitted, and the remaining portion is reflected. A device can capture the reflected and transmitted parts of the energy. Electronic devices may quickly acquire monochrome or color digital pictures utilizing charge-coupled device (CCD) or complementary metal oxide semiconductor (CMOS) sensors [20].
The various colors that the human eye perceives are a result of the different intensities of stimuli received by each type of cone. Despite the widespread use of RGB, alternative color models such as HSV, HSL, and HIS, which integrate hue, saturation, and value, also exist. Hue is commonly used to describe color, such as the difference between yellow and red. Saturation signifies the intensity of color [21]. The amount of light can vary, creating distinctions between different shades, like dark green and light green, or bark blue and light blue. In this context, value refers to the highest level of R, G, or B, while intensity is the average level of R, G, and B. Lightness, on the other hand, is the average level between the highest and lowest amounts of R, G, or B. In order to improve the image feature, several process techniques can be applied to obtain the image for the study [22].
This method presents a straightforward approach for analyzing color histograms on RGB and/or HSI scales. These tools have facilitated the development of an efficient, rapid, and reliable technique. The authors have introduced the utilization of a smartphone in a Bradford assay, which can determine protein concentration in biological samples. In this method, a smartphone spectrometer is employed, along with a G-Fresnel device that enables miniaturization by combining focusing and dispersion functionalities. This study suggests the creation of an application that can be used for analyzing and calibrating data from digital images taken with Android smartphones and Windows phones. The application will utilize simple linear regression and principal component analysis for univariate calibration and exploratory analysis [22].
The present study was aimed to determine isoniazid in tablets by the digital image colorimetry method using the photometric Pro application and comparing it with spectrophotometer. Isoniazid is a pyridine-carbohydrazide molecule (Fig. 1) used as an antitubercular medicine. INH exhibits solubility in water, ethanol, and chloroform, whereas it is insoluble in ether or benzene. It inhibits mycolic acid synthesis, which is an integral component of the bacterial cell wall. It shows a bactericidal effect on both intracellular and extracellular Mycobacterium tuberculosis. INH selectively inhibits the enoyl reductase enzyme by forming a covalent bond with the NAD co-factor of InhA in M. tuberculosis.
Methods
The Folin–Ciocalteu (FC) reagent was procured from SD Fine Chemicals Pvt. Ltd. The isoniazid bulk drugs were purchased from Medico Remedies Ltd. The isoniazid pills, made by MacLeod’s pharmaceuticals Ltd., were obtained from a local pharmacy. The present investigation utilized a Shimadzu UV-1700 UV–visible spectrophotometer as a reference instrument. An Android smartphone equipped with the Photometrix Pro application was utilized for examination. 20% aqueous sodium carbonate solution; FC reagent solution (FC: water in 1:1 v/v) were utilized for this study.
100 ppm standard stock solution was prepared with distilled water as solvent. Sample stock solution was prepared by taking 20 tablets of INH, which were weighed and crushed into powder. A powder equivalent to 150 mg of INH was weighed, and a 100 ml solution was prepared using distilled water as a solvent. 1 ml of the prepared solution was pipetted into a 10 ml volumetric flask and the volume was made with distilled water.
Procedures
UV–visible spectrometry method
A volume of 0.5–2.5 ml of INH standard stock solution was pipetted into 10 ml volumetric flasks, and distilled water was added to bring the volume approximately to 5 ml. Then, 2 ml of FC reagent solution and 2 ml of sodium carbonate solutions were added, followed by covering with lids and keeping aside for 10 min. Then, the volumes were made up to the mark with distilled water.
Figure 2 demonstrates the use of water to raise the volume to the suitable level. A conventional solution was scanned using the visible wavelength range. The spectrum was used to identify the wavelength with the greatest absorption, which is commonly referred to as λmax. The absorbance of each solution was determined relative to a reagent blank that was prepared in a similar fashion but without INH [23].
Digital colorimetric method
In order to ensure an even distribution of light, LED lamps (2 watts) were inserted onto the upper surface of a sealed chamber. A perforated area was included on the front for securing the smartphone in order to capture images. The identical solutions that were employed for UV–visible spectroscopy were also utilized for digital image colorimetry. The closed-chamber contained the standard solutions, which were prepared in varying concentrations. The samples were the focus of the camera through the utilization of the Photometrix Pro application. The captured images underwent direct analysis with a 16 × 16 pixel region of interest selected, and the application extracted the data required for eight channels, i.e., R, G, B, H, L, S, I, V and each of which corresponded to a distinct color space model. Following an analysis of the obtained results, the optimal channel was chosen. The RGB signal was determined by averaging the values of the signals transmitted through the R, G, and B channels. Figure 3 depicts the specific parameters utilized in the Photometrix Pro application [22, 24,25,26,27].
Validation parameters
Linearity A volume of 0.5–2.5 ml of isoniazid standard stock solutions was transferred from the take solution range into 10 ml volumetric flasks. Two milliliters of the prepared reagents were added to each volumetric flask, and after a 10 min period, the volume was adjusted to 10 ml using distilled water. Using Photometrix Pro, the images of the prepared solutions were analyzed and a calibration graph was generated.
Accuracy Accuracy was done by assessing % recovery of the drug from the formulation. It was done by spiking the standard stock solution into sample solution at different levels, such as 80, 100, and 120%. The prepared solutions were analyzed in photometrix pro app, and the %RSD values were calculated.
Precision Take 1.5 ml of standard, then pass it into the 10 ml volumetric flask, then add 2 ml of FC reagent and 2 ml sodium chloride after 10 min make the volume to 10 ml with distilled water. The procedure was repeated to prepare six samples. The samples were analyzed and the %RSD values were calculated.
LOD (Limit of Detection) LOD was calculated by using the formula LOD = 3.3 σ/s, where σ is the standard deviation of the intercept, and s is the slope obtained from linearity.
LOQ (Limit of Quantification) LOD was calculated by using the formula LOD = 10 σ/s, where σ is the standard deviation of the intercept and s is the slope obtained from linearity.
Greenness profile
Greenness of the developed analytical method was analyzed using Analytical Eco-scale (AES), AGREE, and BAGI tools [28,29,30]. AES relies on allotting penalty point to each aspect of environmental hazard and thereby reducing the penalty points from the total 100 score [31, 32]. AGREE is an application, which gives the pictogram in the form of a circle, dividing into 12 parts signifying 12 principles of GAC [33] and thus showing the overall greenness score in the center of circle [34]. BAGI (Blue Applicability Grade Index) evaluates the practicability of the method and gives the score in the range of 25–100 [35].
Results
Preliminary investigations
The FC reagent contains a special acid that, when combined with INH and sodium carbonate, produces a blue colored complex which can be detected at 760 nm. The FC reagent consists of 3H2O, P2O5, 13WO3, 5MoO3, and 10H2O. The presence of INH will reduce the ability of the FC reagent to reduce oxygen present in tungstate and molybdate, which results in the formation of blue color species. The FC technique involves a redox reaction between INH and ferric chloride, which takes place in the presence of potassium ferricyanide under mildly acidic conditions. The reaction results in a blue hue, with the most significant absorption taking place at 760 nm. The process of color development begins with the reduction of iron (III) in ferric chloride to iron (II), which then reacts with ferricyanide to produce Prussian blue. Look at the ultraviolet spectrum displayed in Fig. 4.
Smartphone-based measurement
The research was conducted utilizing the Photo Metrix PRO® application, which supports evaluation in four distinct color spaces: RGB, HSL, HSV, and HSI. This indicates that outcomes are acquired for every solution across the following channels: R, G, B, H, S, L, V, and I. The solutions prepared for obtaining the calibration curve were evaluated through measurements conducted on three smartphones (S1, S2, S3), and the obtained results were subsequently compared using a spectrophotometer. Certain analytical parameters were computed, calibration graphs were generated, and linearity was assessed in accordance with the obtained results. Figures 5 and 6 illustrate the linearity graphs of the spectrophotometric and DIC methods, respectively. The linearity results shown by spectroscopic method and colorimetric method are comparable and have shown same R2 value of 0.993. This indicates the employed DIC method also following Beer–Lambert law same as spectroscopy. The precision and accuracy results are presented in Tables 1, 2, 3, and 4. The comparative results of all the validation parameters performed with spectrophotometer and digital image colorimetry are shown in Table 5.
Greenness of DIC method
Greenness of the developed DIC method was assessed by green metric tools Analytical Eco-scale, AGREE, and BAGI. AES gives the result in the form of points, i.e., 89 (Table 6). By assessing with AGREE tool, the method secured a score of 0.74 (Fig. 7), whereas with the BAGI assessment, the method achieved a score of 80.0 (Fig. 8).
Discussion
The concentration of isoniazid had a significant impact on the color intensity of the calibration solutions that were evaluated. Depending on the amount of drug present, the color of the solution ranged from blue to a grayish-blue. As a result of the change in blue, it was anticipated that the B channel from the RGB color space would produce favorable outcomes, followed by the hue channel. Upon closer inspection, it is clear that the forecast that was made for channel B has been confirmed. For this channel, the best results were produced by using each smartphone. These results were attained in terms of linearity range, precision, and accuracy. Furthermore, the data that were received on the remaining seven channels did not permit the fitting of any trend line in a significant portion of the cases. As a consequence of this, the output from channel B was taken into consideration for the determination of isoniazid.
There are differences between the B channel and the findings that were obtained for each smartphone. In comparison to the data obtained by other technologies, the findings obtained by smartphone 1 are more precise and accurate. The resolution of the camera that was used for the research appears to play a significant part in colorimetric analysis that is based on smartphones, which directly affects the quality of the images. The camera resolution of smartphone 1 is 108 megapixels, whereas the resolution of smartphone 2 is 32 megapixels. Despite the fact that the smartphone 2 and the smartphone 3 were produced by separate businesses, the resolution of their cameras is the same (48 megapixels against 16 megapixels). As the method greenness assessed by using green tools showed 89 points by AES assessment, 0.74 by AGREE assessment and 80.0 by BAGI assessment, it indicates that the method is eco-friendly. The portability of the DIC method is an added advantage to the present method, which is one of the important principles of GAC.
Conclusions
The purpose of this study was to establish whether or not it would be possible to use digital image colorimetry conducted on a smartphone to identify the presence of isoniazid by analyzing the color interaction with FC reagent. Analyses were performed on the results that were acquired in relation to the medicine. The determinations were obtained through the use of digital imaging technologies which were present on three distinct smartphones. A comparison was done between the various systems that were involved. The PhotoMetrix PRO is a photographic measuring instrument that is on par with those used by professionals. There is evidence that the application that is based on smartphones offers a great deal of benefits. Image colorimetry in digital format is the subject of this conversation. On top of that, it has been demonstrated. The results obtained with the B were the most exceptional possible. Users are able to access the channel through the usage of this application, regardless of the particular type of their smartphone. There is a sufficient amount of sensitivity displayed by the approaches that are given in this research. The acquired analytical parameters for colorimetry through the use of smartphone-based digital picture analysis reveal that they are comparable to spectrophotometric methods published in the current literature for the purpose of quantifying isoniazid in pharmaceutical formulations. A validation of the approach was accomplished by analyzing isoniazid in both its conventional formulation and tablet form. The findings that were obtained for both the model and the real samples are considered to be sufficient, which confirms the analytical value of the technique that was recommended for drug analysis. Eco-friendly nature of the developed DIC method, assessed by green metrics proved its greenness. To the best of our knowledge, this work is the first attempt to measure isoniazid levels in pharmaceuticals by employing smartphone-based digital imaging colorimetry. This is the case, according to our current understanding.
Availability of data and material
The data that support the findings of this study are available from the corresponding author, upon reasonable request.
Abbreviations
- AES:
-
Analytical eco-scale
- AGREE:
-
Analytical GREEnness
- BAGI:
-
Blue applicability grade index
- UV–vis:
-
Ultraviolet–visible
- DIC:
-
Digital image colorimetry
- RGB:
-
Red–green–blue
- HSL:
-
Hue–saturation–lightness
- HSV:
-
Hue–saturation–value or brightness
- HIS:
-
Hue–intensity–saturation
- CCD:
-
Charge-coupled device
- CMOS:
-
Complementary metal oxide semiconductor
- INH:
-
Isoniazid
- FC:
-
Folin–Ciocalteu
- RSD:
-
Relative standard deviation
- LOD:
-
Limit of detection
- LOQ:
-
Limit of quantification
- SD:
-
Standard deviation
- SE:
-
Standard error
References
Akash MSH, Rehman K (2020) Essentials of pharmaceutical analysis. Springer Nature Singapore, Singapore
Begum SK, Raju D, Rao N (2013) Simultaneous estimation of rifampicin and isoniazid in combined dosage form by a simple UV spectrophotometric method. Pharm Lett 5:419–426
Pawar PY, Lagad AV, Bahir SN et al (2012) Simultaneous UV spectrophotometric method for estimation of isoniazid and pyridoxine in tablet dosage form. Der Pharma Chemica 4:749–754
Shah U (2014) UV spectrophotometric and RP- HPLC methods for simultaneous estimation of Isoniazid, rifampicin and piperine in pharmaceutical dosage form. Int J Pharm Pharm Sci 6:274–280
Niranjan Prabhu SS, Dibu J, Wilfred P et al (2020) Quantitative estimation of isoniazid content in the commercially available and government-supplied formulations. Indian J Tuberc 67:94–97. https://doi.org/10.1016/j.ijtb.2018.10.002
Qader TA, Abdel-Jabbar H, Ismail B (2022) Spectrophotometric estimation of isoniazid using copper complexes for the Schiff base. AIP conf Proc 2394:040005
Tilinca M, Hancu G, Mircia E et al (2017) Simultaneous determination of isoniazid and rifampicin by UV spectrophotometry. Farmacia 65:219–224
Zareie Z, Nasirizadeh N, Mirjalili M et al (2022) Highly sensitive and selective voltammetric detection of isoniazid drug based on graphene oxide-gold nanourchin-poly(aniline) nanocomposite. Measurement 189:110431. https://doi.org/10.1016/j.measurement.2021.110431
Barbosa PFP, Mastelaro VR, Carmo DR (2024) A new hybrid β-cyclodextrin/PAMAM G.0 as an electrochemical sensor for isoniazid detection. J Mater Eng Perform. https://doi.org/10.1007/s11665-023-09114-7
Liu M, Jia M, Li D (2020) Preparation of a novel electrochemical sensor for isoniazid determination. Int J Electrochem Sci 15:10141–10156. https://doi.org/10.20964/2020.10.67
Imran A, Chandran SR (2020) Method development and validation for simultaneous estimation of emtricitabine, tenofovir disoproxil fumarate and isoniazid in bulk and pharmaceutical dosage form By RP-HPLC. J Pharm Sci Res 12:574–579
Rajeswari B, Saritha N, Devanna N (2020) Method development and validation for the simultaneous estimation of ethambutol and isoniazid by using RP-HPLC. Res J Life Sci Bioinform Pharm Chem Sci 6:24–35. https://doi.org/10.26479/2020.0602.02
Panda B, Dikkatwar M (2020) Application of HPLC For simultaneous determination of isoniazid, rifampicin and pyrazinamide in a fixed dose formulation. J Adv Sci Res 11:248–253
Brozyna-Heredia IY, Ganoza-Yupanqui ML, Moreno-Exebio L, Dos Santos JL (2022) Chromatographic methods for the determination of rifampicin, isoniazid, pyrazinamide, ethambutol, and main metabolites in biological samples: a review. Crit Rev Anal Chem 29:1–16. https://doi.org/10.1080/10408347.2022.2150071
Agoston GA (1979) Color theory and its application in art and design. Springer, Berlin Heidelberg, Berlin, Heidelberg
Passos LCM, Saraiva MFS (2019) Detection in UV-visible spectrophotometry: Detectors, detection systems, and detection strategies. Measurement 135:896–904. https://doi.org/10.1016/j.measurement.2018.12.045
Abughrin S, Alshana U, Caleb J (2022) Smartphone digital image colorimetry for the determination of aluminum in antiperspirant products. Turk J Pharm Sci 19:618–625. https://doi.org/10.4274/tjps.galenos.2021.18828
Böck FC, Helfer GA, da Costa Ben A et al (2020) PhotoMetrix and colorimetric image analysis using smartphones. J Chemom 34:e3251. https://doi.org/10.1002/cem.3251
Fan Y, Li J, Guo Y et al (2021) Digital image colorimetry on smartphone for chemical analysis: a review. Measurement 171:108829. https://doi.org/10.1016/j.measurement.2020.108829
Centen P (2014) Complementary metal-oxide-semiconductor (CMOS) and charge coupled device (CCD) image sensors in high-definition TV imaging. High Performance Silicon Imaging. Elsevier, Netherlands, pp 373–410
Doncean G, Doncean M, Sulenco A (2021) Abstract mathematical models used in colour management. J Public Adm Fin and Law 2021:168–180. https://doi.org/10.47743/jopafl-2021-22-13
Helfer GA, Magnus VS, Böck FC et al (2016) PhotoMetrix: an application for univariate calibration and principal components analysis using colorimetry on mobile devices. J Braz Chem Soc 28:328–335. https://doi.org/10.5935/0103-5053.20160182
Swamy N, Prashanth KN, Basavaiah K (2014) Redox-reaction based spectrophotometric assay of isoniazid in pharmaceuticals. ISRN Ana Chem 2014:1–11. https://doi.org/10.1155/2014/717019
Mane Y, Mashru R (2021) New smartphone based colorimetric method development and validation of emtricitabine in bulk and tablet dosage form. J Drug Del Ther 11:35–40. https://doi.org/10.22270/jddt.v11i4.4933
da Costa A, Helfer G, Barbosa J et al (2021) PhotoMetrix UVC: a new smartphone-based device for digital image colorimetric analysis using PLS regression. J Braz Chem Soc 32:675–683. https://doi.org/10.21577/0103-5053.20200199
Prajapati DM, Mashru R (2022) Development and validation of new smartphone based colorimetric method for metoprolol succinate in bulk and tablet dosage Form. J Drug Del Ther 12:108–115. https://doi.org/10.22270/jddt.v12i3.5469
Mermer K, Paluch J, Kozak J (2022) Smartphone-based digital image colorimetry for the determination of vancomycin in drugs. Monatshefte für Chemie-Chem Mon 153:801–809. https://doi.org/10.1007/s00706-022-02964-2
Yenduri S, Koppuravuri NP (2024) Assessment and comparison of sustainability aspects of UV-spectroscopy methods for simultaneous determination of anti-hypertensive combination. Green Anal Chem 9:100108. https://doi.org/10.1016/j.greeac.2024.100108
Yenduri Suvarna NPK (2023) Recent research trends in pharmaceutical science. Integrated Publications, Delhi
Yenduri S, Varalakshmi HN, Koppuravuri NP (2024) Assessment and comparison of greenness of UV-spectroscopy methods for simultaneous determination of anti-hypertensive combination. Int J Pharm Ed Res 58:s543–s551. https://doi.org/10.5530/ijper.58.2s.56
Gałuszka A, Migaszewski ZM, Konieczka P, Namieśnik J (2012) Analytical Eco-Scale for assessing the greenness of analytical procedures. TrAC Tr Anal Chem 37:61–72. https://doi.org/10.1016/j.trac.2012.03.013
Mohamed HM, Lamie NT (2016) Analytical eco-scale for assessing the greenness of a developed RP-HPLC method used for simultaneous analysis of combined antihypertensive medications. J AOAC Int 99:1260–1265. https://doi.org/10.5740/jaoacint.16-0124
Yenduri S, Sulthana H, Koppuravuri NP (2023) Sustainablity evaluation of existed HPLC based analytical methods for quantification of amlodipine besylate and telmisartan using RGB model: A whiteness approach. Green Anal Chem 6:100074. https://doi.org/10.1016/j.greeac.2023.100074
Pena-Pereira F, Wojnowski W, Tobiszewski M (2020) AGREE—analytical GREEnness metric approach and software. Anal Chem 92:10076–10082. https://doi.org/10.1021/acs.analchem.0c01887
Manousi N, Wojnowski W, Płotka-Wasylka J, Samanidou V (2023) Blue applicability grade index (BAGI) and software: a new tool for the evaluation of method practicality. Green Chem 25:7598–7604. https://doi.org/10.1039/D3GC02347H
Acknowledgements
Authors are thankful to Sri Adichunchanagiri College of pharmacy for the support throughout the study.
Funding
No funding was provided for the present work.
Author information
Authors and Affiliations
Contributions
YS has designed the work, collected the data and methods, and prepared the draft copy of manuscript. NPK has supervised the work and reviewed the manuscript and references.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable.
Consent for publication
The authors declare no conflict of interest.
Competing interests
Not applicable.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Yenduri, S., Prashant, K.N. Estimation of isoniazid by digital image colorimetry: an integration of green chemistry and smartphone technology. Futur J Pharm Sci 10, 128 (2024). https://doi.org/10.1186/s43094-024-00703-4