Skip to main content

Table 5 Model analysis and model fitted statistical values

From: Development, optimization, and in vitro evaluation of atorvastatin calcium and vinpocetine codelivery by solid lipid nanoparticles for cancer therapy

CQA parameters

Model suggested

Model significance value

Lack of fit value

R2 value

Model's mathematical equation

Particle Size

Quadratic model

< 0.0001

2628.2

0.974

398.12 + 45.48 * A − 38.62 * B − 7.51 * C − 27.13 * AB − 14.38 * AC + 2.62 * BC + 35.29A2 + 2.90 * B2 + 44.13 * C2

% EE (ATS)

Cubic model

0.0214

34.53

0.924

54.89 + 0.9656 * A + 3.84 * B − 1.20 * C  −  0.1963 * AB + 2.10 * BC + 0.5081 * A2 + 0.663 * B2 − 1.97 * C2

% EE (VIN)

Cubic model

 < 0.0001

0.0390

0.999

57.5 + 1.33 * A + 3.18 * B − 1.47 * C + 3.06 * AB + 1.03 * AC + 5.83 * BC − 2.11 * A2 + 0.2684 * B2 − 5.64 * C2

% DL

Quadratic model

 < 0.0001

1.24

0.951

5.54–1.20 * A + 0.365 * B − 0.149 * C 0.0288 * AB + 0.1512 * AC + 0.3037 * BC + 0.2003A2 + 0.0889 * B2 − 0.238 * C2

  1. EE, entrapment efficiency; DL, drug loading; A, drug lipid ratio; B, surfactant co surfactant ratio; C, homogenization speed