Skip to main content

Table 5 Validation and stability parameters of the chemometrics optimized RP-HPLC method

From: Experimental design optimization of RP-HPLC method for simultaneous estimation of metsulfuron-methyl, chlorantraniliprole and chlorimuron-ethyl residues in stems of Oryza sativa

Parameters

Metsulfuron-methyl

Chlorantraniliprole

Chlorimuron-ethyl

Linearity correlation coefficient

Slope = 2966.9

Intercept = 13,062

(R2) = 0.999

Slope = 62,403

Intercept = 13,062

(R2) = 0.999

Slope = 3513.5

Intercept = 13,062

(R2) = 0.999

Precision

Mean = 934,911.8

SD = 7337.7

%RSD = 0.8

Mean = 743,186.5

SD = 2511.5

%RSD = 0.3

Mean = 1,107,995.2

SD = 8554.2

%RSD = 0.8

Intermediate precision

Mean = 960,417.7

SD = 8148.4

%RSD = 0.8

Mean = 934,911.8

SD = 3655.2

%RSD = 0.5

Mean = 934,911.8

SD = 3722.7

%RSD = 0.3

Accuracy (Mean recovery)

99.95

99.86

100.27

LOD (S/N ratio)

3.00

2.96

3.02

LOQ (S/N ratio)

9.98

10.02

10.00

Acid degradation (%)

3.26

2.50

10.89

Base degradation (%)

1.58

1.05

9.99

Oxidative degradation (%)

3.83

5.19

10.52

Reduction (%)

1.71

3.85

8.21