Skip to main content

Design of experiments and white analytical chemistry-driven green and sensitive spectrofluorimetric estimation of pregabalin in its pharmaceutical dosage forms and spiked human plasma

Abstract

Background

Pregabalin (PGB) is a medication with anticonvulsant, analgesic and anxiolytic properties, employed in the treatment of epilepsy, neuropathic pain, fibromyalgia, restless leg syndrome, opioid withdrawal syndrome and generalized anxiety disorder. Several spectrofluorimetric techniques have been documented for the determination of PGB in pharmaceutical dosage forms. However, these published methods typically involve the use of expensive and toxic organic solvents and reagents, as well as high reaction temperatures for PGB analysis. These components pose risks to aquatic life and the environment, making them less environmentally friendly and user-friendly. A recent advancement in analytical chemistry has introduced a white analytical approach, providing an economical, eco-friendly and user-friendly method for the development of analytical procedures.

Objectives

Therefore, a green and sensitive spectrofluorimetric determination of PGB, guided by white analytical chemistry principles, has been conducted utilizing distilled water as an environmentally friendly solvent.

Methods

The establishment of the spectrofluorimetric method involved employing the design of experiments approach to ensure a robust, precise and accurate estimation of PGB. Response surface analysis and optimization of critical procedural variables and responses were carried out using the central composite design. The validation of the developed method adhered to the guidelines outlined in ICH (International Council for Harmonization) Q2 (R1) and M10.

Results

The established spectrofluorimetric method was utilized to determine the PGB content in commercially available formulations and human plasma samples spiked with PGB. The obtained results were in accordance with the labeled claim of PGB in the formulations. The recovery of PGB in the spiked human plasma samples ranged from 85 to 90% of the spiked amount.

Conclusions

The greenness profiles of the published and suggested spectrofluorimetric methods for PGB estimation were evaluated and compared using the AGREE calculator, GAPI software and ESA tool. The suggested method demonstrated sensitivity, robustness, environmental friendliness and user-friendliness.

Background

Recently introduced into the literature, white analytical chemistry is an approach for the development and evaluation of accurate, sensitive, precise, environmentally friendly and cost-effective analytical methods for estimating drugs and their dosage forms. White analytical chemistry incorporates the key principles of green analytical chemistry in method development. It involves an RGB (red, green and blue) model-based assessment of the developed analytical method. The red (R) model-based assessment comprises four principles: R1—scopes and applications, R2—accuracy, R3—precision and R4—linearity and sensitivity. The green (G) model-based assessment includes the four major principles of green analytical chemistry: G1—environmental impact, G2—energy consumption, G3—waste generation and G4—health impact of the analytical method. The blue (B) model-based assessment includes four major principles: B1—time efficiency, B2—cost efficiency, B3—simplicity of the method and B4—instrument handling for the assessment of the analytical method [1].

Within the pharmaceutical industry, chromatographic analytical methods are frequently employed for the quality control and routine analysis of both drug substances and drug products. In the course of chromatographic analysis of drug samples, toxic organic solvents like chloroform, acetonitrile, methanol, toluene, etc., have traditionally been utilized and subsequently left as organic waste in the environment. Adhering to standards outlined in the Indian Pharmacopoeia, ICH (International Council for Harmonization) Q3C guidelines and published solvents selection guides, these organic solvents are recognized as harmful to aquatic animal life and environmentally hazardous. In line with the principles of green and white analytical chemistry, there is a concerted effort to reduce, eliminate and recycle the consumption and wastage of such toxic organic solvents during the development and life cycle management of analytical methods, aiming to preserve the environment [2,3,4,5].

The design of experiments (DoE) is a systematic methodology employed in the development of analytical methods to ensure robustness, precision and accuracy. As outlined in the ICH Q14 guideline, the incorporation of the design of experiments approach is a regulatory requirement for the registration and approval of new drug substances and products. Additionally, the design of experiments is a valuable tool for the implementation of white analytical chemistry, aiding in the development of analytical methods that are both robust and precise. Furthermore, the application of the design of experiments proves beneficial in minimizing the consumption of organic solvents during the development of analytical methods. Recent literature reveals the emergence of numerous published analytical methods that integrate hybrid principles of design of experiments, green analytical chemistry and white analytical chemistry [6,7,8,9,10].

Pregabalin (PGB) is a medication with anticonvulsant, analgesic and anxiolytic properties, prescribed for conditions such as epilepsy, neuropathic pain, fibromyalgia, restless leg syndrome, opioid withdrawal syndrome and generalized anxiety disorder [11]. Numerous methods, including spectrophotometric, RP-HPLC (reversed-phase high-pressure liquid chromatographic) and LC–MS/MS, have been documented in the literature for estimating PGB in pharmaceutical dosage forms and conducting bioanalysis [12,13,14,15,16,17,18,19,20,21,22]. However, these analytical approaches involve the use of toxic organic solvents, posing environmental risks. Spectrofluorimetric methods, recognized for their sensitivity, specificity, accuracy and precision in drug sample estimation, offer a more environmentally friendly alternative with reduced organic solvent usage, time and cost. In the context of implementing the principles of white analytical chemistry, the spectrofluorimetric method stands out as an ideal choice for green, accurate, sensitive, precise and economical analysis of drug samples. Notably, PGB is a nonfluorescent drug molecule, necessitating derivatization for the development of a spectrofluorimetric method. Recent literature has featured various spectrofluorimetric methods utilizing different derivative reagents as fluorescent probes for PGB estimation [23,24,25,26,27,28]. However, some published spectrofluorimetric methods employ toxic organic solvents, high reaction temperatures and toxic reagents, generating over 100 mL of organic waste. Additionally, the sensitivity of certain published spectrofluorimetric methods is limited to the microgram level.

Therefore, a sensitive, robust and environmentally friendly spectrofluorimetric method has been developed for the estimation of PGB, utilizing safe solvents and eliminating the need for derivative reagents. The development of this spectrofluorimetric method followed a comprehensive strategy based on the principles of white analytical chemistry and the design of experiments. The design of experiments approach was implemented using a central composite design, which facilitated response surface analysis and optimization of the spectrofluorimetric method. The developed method underwent validation in accordance with ICH Q2 (R1) and M10 guidelines. Application of the developed spectrofluorimetric method included the assay of both marketed formulations and spiked human plasma samples. To assess and compare the greenness and whiteness profiles of the published and developed spectrofluorimetric methods, various tools and models such as the AGREE (Analytical Greenness) calculator, ESA (Eco-scale Assessment) tool, GAPI (Green Analytical Procedure Index) and RGB (red, green and blue) models were employed.

Methods

Instruments and softwares

The determination of PGB was conducted utilizing a Spectrofluorometer Shimadzu RF-5301 PC model, obtained from Toshvin Analytical Private Limited in Vapi, Gujarat, India. The spectrum of PGB was recorded using a UV–Visible spectrophotometer 3092 model (Lab India Private Limited, Mumbai, Maharashtra, India). For precise weighing, a single pan digital analytical balance, acquired from Shimadzu Scientific Instruments (India) Private Limited in Bangalore, India, was employed. The response surface modeling based on Design of Experiments (DoE) was carried out using MINITAB 18 software (trial version). To evaluate the environmental friendliness of the method, the AGREE calculator (accessible at https://mostwiedzy.pl/AGREE) was employed. Additionally, the greenness profile of the method was assessed using Complex GAPI software, which can be accessed at mostwiedzy.pl/complexgapi.

Reagents and materials

The PGB API (Active Pharmaceutical Ingredient) with 99.98%W/W purity was received as a complimentary gift sample from Vapi Care Pharma Private Limited in Gujarat, India. High-quality double-distilled water was meticulously prepared in the Quality Assurance Laboratory at our institute. To facilitate filtration, membrane filters (0.45 µm) and sample syringe filters (0.22 µm) were acquired from Pall India Private Limited, located in Andheri, Mumbai, India. The pharmaceutical dosage forms of PGB (Pregazo 75 capsule—contains 75 mg PGB, Pregal 75 capsule—contains 75 mg PGB, and Pregadd tablets—contains 50 mg PGB) were procured from the local market in Surat, Gujarat, India.

Establishing calibration curve for assay of marketed formulations

A standard solution of PGB (1000 μg/ml) was prepared by dissolving 10 mg of PGB in distilled water in a 10-mL volumetric flask. Subsequent dilutions were carried out with distilled water to generate concentrations ranging from 1.0 to 25 µg/ml. Consequently, 100 µL from the working solution (10 to 25 µg/ml) of PGB was transferred into a series of 10-mL volumetric flasks and topped up to the mark with borate buffer of pH 10.0, resulting in the final concentration range of 10–250 ng/mL. The fluorescence intensity was measured at an emission wavelength of 410 nm using an excitation wavelength of 230 nm. A blank experiment was conducted in a similar manner without the presence of PGB.

Establishing a calibration curve through the spiking of PGB to human plasma samples

In each 100 µL aliquot of human plasma, a 10 µL portion from distinct working standard solutions (100–2500 µg/mL) was individually introduced, thoroughly mixed and vortexed for 15 min. To extract PGB from the human plasma, 3.0 mL of methanol was added as a precipitating agent and mixed for an additional 15 min. Following complete precipitation, the resulting samples were diluted to a final volume of 10 mL with methanol. Subsequently, each sample underwent centrifugation at 4000 RPM for 15 min. A 1.0 mL aliquot from the supernatant of each solution was filtered through a 0.22 µm syringe filter and transferred into a series of 10-mL volumetric flasks, completed to the mark with borate buffer of pH 10.0, resulting in the final concentration range of 10–250 ng/mL. The fluorescence intensity was measured at an emission wavelength of 410 nm using an excitation wavelength of 230 nm. A blank experiment was conducted similarly without the presence of PGB.

Implementing design of experiments approach in method development

Following preliminary experiments, critical procedural variables and method performance attributes (responses) were identified for the development of the intended method. These critical method variables were examined for their main effects, two-way interactions and quadratic effects on selected responses using central composite design through Minitab 18 software. Navigating the analytical design space was allowed for the optimization of responses in the targeted spectrofluorimetric method for estimating PGB. Mean response surface analysis was conducted to delineate the analytical design space and validate the model.

Analysis of pregabalin in marketed formulations

A sample equivalent to 10 mg of PGB was taken from each pharmaceutical dosage form of PGB. This sample was dissolved, diluted to 10 mL with distilled water and then filtered. Subsequently, a 1.0 mL aliquot was further diluted to 10 mL with distilled water. From this solution, another 1.0 mL aliquot was diluted to 10 mL with distilled water. A 100 µL aliquot of the sample was then transferred into a 10-mL volumetric flask and completed to the mark with borate buffer at pH 10.0. The fluorescence intensity was measured at an emission wavelength of 410 nm using an excitation wavelength of 230 nm. A blank experiment was conducted in a similar manner, excluding the presence of PGB sample.

Results

Defining the analytical target profile for the design of experiments approach

The spectrofluorimetric method was developed to estimate PGB in its pharmaceutical dosage forms and spiked human plasma samples, employing environmentally safe and sustainable solvents. The developed method was designed to yield optimal fluorescence intensity and % recoveries of PGB, ensuring sensitive, selective and specific estimation in the proposed matrices. Consequently, fluorescence intensity and % recovery of PGB have been identified as crucial responses in the development of the targeted spectrofluorimetric method (Fig. 1).

Fig. 1
figure 1

Pareto chart analysis using central composite design and Minitab 18 software. A Pareto chart showing significant main effects and quadratic effects of critical procedure variables on fluorescence intensity—Response R1 and B Pareto chart showing significant main effects and quadratic effects of critical procedure variables on % recoveries—Response R2

Utilizing response surface analysis for method optimization

The Minitab 18 software proposed thirteen experimental runs (refer to Table 1), which were subsequently conducted in the laboratory. The recorded responses from these experimental runs were analyzed through ANOVA, multiple regression analysis and response surface analysis using the software. According to the ANOVA results (refer to Table 2), the main effects of critical procedure variables A and B were found to be significant for responses R1 and R2, along with significant quadratic effects of critical procedure variables A and B. However, the two-way interactions of critical procedure variables A and B were determined to be nonsignificant for responses R1 and R2. The multiple regression analysis revealed R-squared, adjusted R-squared and predicted R-squared values for responses exceeding 0.9, with the difference between adjusted R-squared and predicted R-squared being less than 0.2. These outcomes suggest that the selected models were well suited for predicting responses R1 and R2. The 2D and 3D response surface contour plots (refer to Figs. 2A, B, 3A, B) illustrate multidimensional interactions and the quadratic relationship between critical procedure variables (A and B) and responses R1 and R2. The analytical design space was navigated to achieve maximum fluorescence intensity and % recovery of PGB, aligning with the analytical target profile of the method, using overlaid response surface plots.

Table 1 Design metrics and measured responses for DoE-based response surface analysis and optimization of critical procedure variables (CPVs) using central composite design by Minitab 18 software
Table 2 Analysis of variances (ANOVA) for study of significant main effect, two-way interactions and quadratic effects of critical procedure variables using central composite design and Minitab 18 software
Fig. 2
figure 2

DoE-based response surface analysis of critical method variables and responses using central composite design. A 2D contour plot showing multidimensional interactions between critical procedure variables A and B with fluorescence intensity—Response R1. B 2D contour plot showing multidimensional interactions between critical method variables A and B with % recoveries—Response R2. C Analytical design space for desirable maximum fluorescence intensity and %recovery of PGB

Fig. 3
figure 3

DoE-based response surface analysis of critical method variables and responses using central composite design and Minitab 18 software. A 3D contour plot showing multidimensional interactions between critical procedure variables A and B with fluorescence intensity—Response R1. B 3D contour plot showing multidimensional interactions between critical method variables A and B with % recoveries—Response R2. C Analytical design space for desirable maximum fluorescence intensity and %recovery of PGB

Employing the mean response surface method to define the analytical design space

Following an examination of the overlaid response surface plots, the analytical design spaces, directed toward achieving maximum fluorescence intensity and % recovery of PGB, were scrutinized for accuracy and precision in predicting responses R1 and R2 using the mean response surface method. The visual representation of these navigated analytical design spaces is depicted in Figs. 2C and 3C, highlighted in white shades. Subsequently, the experimental runs recommended by the software were executed in the laboratory, and the actual responses were analyzed for their %RSD (n = 3). The %RSD for all experimental runs was determined to be less than 2%, indicating the accurate and precise prediction of responses R1 and R2 by the suggested models.

Spectrofluorimetric method validation

The method's specificity was confirmed by comparing fluorescence spectra among various samples, including blank and standard PGB. Blank samples exhibited no interference from excipients or human plasma matrices (Refer Additional file 1: Fig. S2). Linearity was established through five repetitions of calibration curve procedures, demonstrating a linear relationship within the 10–250 ng/mL concentration range, with a correlation coefficient exceeding 0.995 (refer to Figs. 4 and 5). Additionally, % recoveries of PGB from spiked human plasma samples (at 50%, 100% and 150% levels) ranged from 85 to 90%. Evaluations for sample carryover and sample dilution in the estimation of PGB were conducted within spiked human plasma samples. The method's robustness was assessed by varying scanning speed and excitation wavelength, yielding consistent results. Precision studies for both intra-day and inter-day analyses demonstrated the method's reliability in estimating PGB. The method exhibited remarkable sensitivity, with the lowest limit of detection and quantitation determined to be 5.0 ng/mL and 10 ng/mL, respectively, underscoring its capability to detect PGB at nanogram-level concentrations. A summary of the validation parameters is presented in Table 3.

Fig. 4
figure 4

Overlaid fluorescence spectrum showing linearity of PGB over concentration range of 10–50 ng/mL in spiked human plasma at emission wavelength of 410 nm and excitation wavelength of 230 nm

Fig. 5
figure 5

Overlaid fluorescence spectrum showing linearity of PGB over concentration range of 50–250 ng/mL at emission wavelength of 410 nm and excitation wavelength of 230 nm

Table 3 Validation summary of developed spectrofluorimetric method as per ICH guidelines

Formulations assay and spiked human plasma samples analysis

The established method was employed to assay various market formulations of PGB, revealing % assay values for PGB in the formulations within the range of 95% to 105% of the labeled claim of PGB. The presence of excipients did not cause interference in the estimation of PGB. In spiked human plasma samples, the % recovery of PGB was determined to be in the range of 85% to 90%. The matrices of blank human plasma samples did not pose interference in the estimation of PGB.

Discussion

The UV spectrum of PGB in distilled water exhibited two peaks at 210 nm and 230 nm (Refer Additional file 1: Figure S1 for UV spectrum of PGB), respectively. The 210 nm peak corresponded to the π–π* transition, while the 230 nm peak was attributed to the n − π* transition of the primary amine functional group in PGB. Upon excitation at 230 nm, the nitrogen of the amino group led to a fluorescence emission at 410 nm. The fluorescence intensity at 410 nm was employed for a linearity study, revealing a linear relationship at nanogram-level concentrations of PGB. This fluorescence intensity was further examined in buffer solutions spanning a pH range of 1.0 to 12.0, with the highest intensity observed in borate buffer at pH 8–10. The existing literature has detailed spectrofluorimetric methods involving derivatization, often utilizing toxic organic solvents and reagents, and exhibiting sensitivity at microgram levels. Additionally, these methods necessitated high reaction temperatures during the derivatization of PGB, rendering them less user-friendly. Notably, no spectrofluorimetric method in the literature has been reported for the detection and quantification of PGB without the need for derivatization.

A recent development in analytical chemistry advocates for a white analytical chemistry approach, emphasizing the development of green, economical and user-friendly analytical methods. Following the ICH Q14 guideline, the implementation of a design of experiments approach is a regulatory requirement for the registration of new drug products and substances. Despite this, the literature lacks an analytical method for estimating PGB using the white analytical chemistry and design of experiments approach. In response, a robust, green and user-friendly spectrofluorimetric method has been devised for the estimation of PGB in pharmaceutical dosage forms and spiked human plasma samples. This method integrates the principles of white analytical chemistry and the design of experiments approach, aligning with the contemporary trend toward environmentally conscious and efficient analytical methodologies, as suggested by recent developments in analytical chemistry.

Design of experiments using Minitab 18 software

After conducting initial experiments, it was determined that the excitation wavelength (designated as critical procedure variable A) and the pH of the medium (designated as critical procedure variable B) played pivotal roles. These variables were subsequently investigated to establish their graphical relationships with selected responses using response surface methodology. The fluorescence intensity and percentage recovery of PGB were chosen as critical responses for the development of a targeted spectrofluorimetric method. To analyze the identified critical procedure variables, a central composite design was employed, allowing the examination of main effects, two-way interactions and quadratic effects of the variables on the selected responses (R1 and R2). The analytical design space was explored to achieve maximum fluorescence intensity and percentage recovery of PGB in alignment with the analytical target profile of the method, as illustrated through overlaid response surface plots. Following a thorough examination of these plots, the navigated analytical design spaces for maximum fluorescence intensity and percentage recovery of PGB were assessed for accuracy and precision in predicting responses R1 and R2 using the mean response surface method. The optimized range for the excitation wavelength (critical procedure variable A) was determined to be 230 to 240 nm, while the optimized range for the pH of the medium (critical procedure variable B) was identified as 9.0 to 10.0. Consequently, the spectrofluorimetric estimation of PGB was conducted with an excitation wavelength of 230 nm at a pH of 9.0 in a borate buffer.

The developed spectrofluorimetric method has undergone validation in accordance with the guidelines of ICH Q2 (R1) for the assay of pharmaceutical dosage forms, encompassing specificity, accuracy, linearity, precision, LOD, LOQ and robustness. Additionally, the validation of the developed spectrofluorimetric method has been conducted following the ICH M10 guideline for estimating PGB in spiked human plasma samples. The results indicate that the developed method is accurate, precise, robust, sensitive, specific and linear in the estimation of PGB in both its pharmaceutical dosage forms and spiked human plasma samples. All validation parameters align with the standards outlined in the ICH Q2 (R1) and M10 guidelines.

The conventional technique was utilized to assay different commercial formulations of PGB (Pregazo 75 capsule—contains 75 mg PGB, Pregal 75 capsule—contains 75 mg PGB, and Pregadd tablets—contains 50 mg PGB), uncovering assay values for PGB in these formulations falling between 95 to 105% of the stated PGB content. Interestingly, the addition of other substances did not affect the measurement of PGB. When PGB was intentionally added to human plasma samples, its recovery ranged from 85 to 90%. Remarkably, the absence of any interfering substances in blank human plasma samples did not hinder the determination of PGB levels (refer supplementary files for fluorescence spectrum of blank human plasma and reagents). According to the reported LC–MS/MS method [20], the reported linearity range and Cmax value of PGB was found to be 0.1 to 15 µg/mL and 6.925 to 7.477 µg/mL in human plasma. The proposed spectrofluorimetric method was found to be complied with the reported LC–MS/MS method for the estimation of PGB in spiked human plasma samples. The developed method can be extended as sensitive and green analytical tool for pharmacokinetic and bioequivalence study of PGB in human and rat plasma.

Evaluation of spectrofluorimetric methods through white analytical chemistry principles

The comparative analysis of the existing and proposed methods for estimating PGB has been conducted through white analytical chemistry and an RGB model-based scoring system, as detailed in Table 4. The spectrophotometric methods published in the literature were evaluated against the proposed spectrofluorimetric method using both the RGB and WAC scoring systems. The red model-based assessment focused on evaluating the validation efficiency, sensitivity, scope and applicability of spectrofluorimetric methods. Some published spectrofluorimetric methods [24, 26, 27] exhibited sensitivity at the microgram level, earning a Rrd model-based score of 95 out of 100 (refer to Table 4). In contrast, our proposed method and other published spectrofluorimetric methods [22, 23] achieved a perfect score of 100, attributed to their nanogram-level sensitivity and applicability for PGB estimation in marketed formulations and spiked human plasma. This high score reflects their implementation of the design of experiments approach, exceptional sensitivity, % recoveries and applicability for PGB estimation.

Table 4 Comparison and assessment of published and proposed spectrofluorimetric for the estimation of PGB using principles of green and white analytical chemistry

The green model-based scoring and greenness profile assessment of analytical methods utilized the AGREE calculator, GAPI software, NEMI standards and ESA tool. However, the literature suggests that NEMI standards for greenness assessment provide the least accurate information. Therefore, AGREE and GAPI scores were considered for the calculation of the green model-based score. The green model-based scoring system assessed environmental friendliness, with published methods scoring less than 65 out of 100 based on AGREE and GAPI software criteria. The proposed method earned a score of 80 due to its use of environmentally friendly solvents (distilled water and methanol only), reduced organic waste generation and lower power consumption for PGB estimation. In contrast, the published spectrofluorimetric methods required high reaction temperatures and costly organic solvents and derivative reagents.

Assessing time, cost efficiency and user-friendliness through the blue model-based scoring system, published spectrophotometric methods scored 90 out of 100, respectively. The proposed method, which does not require high temperatures or costly derivative reagents and solvents for PGB estimation, achieved a perfect score of 100 for its economical, rapid, user-friendly and straightforward approach. The overall WAC (white analytical chemistry) score, calculated by averaging RGB model scores, for published spectrofluorimetric methods was found to be less than 84 out of 100. In contrast, the proposed method received a score of 93.33 due to its validation efficiency, environmental friendliness, speed, cost-effectiveness and user-friendliness in PGB estimation. A comprehensive comparison of the greenness profile, WAC and RGB model-based scoring is depicted in Fig. 6A, B.

Fig. 6
figure 6

A Greenness profile study of proposed spectrofluorimetric method using AGREE and GAPI software. B Whiteness profile assessment and comparison of published and proposed spectrofluorimetric methods for the estimation of PGB using RGB model score

Conclusions

A hybrid approach, combining principles from white analytical chemistry and design of experiments, was employed for the spectrophotometric estimation of PGB. The resulting method incorporates safe, environmentally friendly and cost-effective solvents. Validation of the developed method encompassed specificity, sensitivity, selectivity, precision, accuracy and linearity in the estimation of PGB. Application of the method to assess PGB in various marketed formulations yielded results in accordance with the labeled claim. Furthermore, the method's applicability was extended to the estimation of PGB in spiked human plasma samples, demonstrating validation in accordance with ICH M10 guidelines. Both the developed and published methods were evaluated for their greenness and whiteness profiles in PGB estimation using RGB model scoring system, AGREE and GAPI software. The proposed method proved to be sensitive, robust, environmentally friendly, economical and user-friendly in estimating PGB across diverse samples. This developed method holds potential for use in pharmacokinetic and pharmacodynamic studies of PGB, presenting an economical and eco-friendly analytical tool for bioanalysis and quality control of PGB pharmaceutical dosage forms in the pharmaceutical industry.

Availability of data and materials

The data will be availed by corresponding author of manuscript on reasonable request.

Abbreviations

ADS:

Analytical Design Space

AGREE:

Analytical Greenness

ANOVA:

Analysis of Variance

DoE:

Design of Experiments

ESA:

Eco-Scale Assessment

GSK:

GlaxoSmithKline

GAC:

Green Analytical Chemistry

GAPI:

Green Analytical Procedure Index

HPLC:

High-Pressure Liquid Chromatography

HPTLC:

High-Performance Thin-Layer Chromatography

ICH:

International Council for Harmonization

LOD and LOQ:

Limit of Detection and Limit of Quantitation

NEMI:

National Environmental Method Index

PGB:

Pregabalin

PDE:

Permitted Daily Exposure

RSM:

Response Surface Modeling

RGB:

Red, Green and Blue

WAC:

White Analytical Chemistry

References

  1. Nowak MP, Weitecha-Posluszny R, Pawliszyn J (2021) White analytical chemistry: an approach to reconcile the principles of green analytical chemistry and functionality. Trends Ana Chem 138:116223. https://doi.org/10.1016/j.trac.2021.116223

    Article  CAS  Google Scholar 

  2. International Council for Harmonization (2016) Q3C (R6) guideline, impurities: a guideline for residual solvent, 1–40

  3. Indian Pharmacopoeia (2018) Volume I, Residual solvents, the Indian pharmacopeia Commission, 987

  4. Byrne FP, Jin S, Paggiola G, Petchey THM, Clark JH, Farmer TJ, Hunt AJ, McElroy CR, Sherwood J (2016) Tools and techniques for solvent selection: green solvent selection guides. Sust Chem Proc 4(7):1–24. https://doi.org/10.1186/s40508-016-0051-z

    Article  CAS  Google Scholar 

  5. Stojanovic J, Krmar J, Otasevic B, Protic A (2023) Resource management in HPLC: Unveiling a green face of pharmaceutical analysis. Arhiv Za Farmaciju 73(2):146–171. https://doi.org/10.5937/arhfarm73-43479

    Article  Google Scholar 

  6. Rana B, Pulusu VS, Shah S (2024) Simultaneous chromatographic estimation of vildagliptin and dapagliflozin using hybrid principles of white analytical chemistry and analytical quality by design. J AOAC Int 107(01):1–15. https://doi.org/10.1093/jaoacint/qsad108

    Article  Google Scholar 

  7. Shahi A, Acharya A, Pulusu VS, Shah S (2023) Implementation of white analytical chemistry–assisted analytical quality by design approach to green liquid chromatographic method for concomitant analysis of anti-hypertensive drugs in human plasma. J Chrom Sci: 1–15. https://doi.org/10.1093/chromsci/bmad054

  8. Pulusu VS, Shah S (2023) Principles of white analytical chemistry and design of experiments to stability-indicating chromatographic method for simultaneous estimation of thiocolchicoside and lornoxicam. J AOAC Int 106(6):1654–1665. https://doi.org/10.1093/jaoacint/qsad082

    Article  PubMed  Google Scholar 

  9. Pulusu VS, Shah S (2023) Red, green, and blue model-based assessment and principles of white analytical chemistry to robust stability-indicating chromatographic estimation of thiocolchicoside and diclofenac sodium. J AOAC Int 106(05):1374–1388. https://doi.org/10.1093/jaoacint/qsad052

    Article  PubMed  Google Scholar 

  10. Pulusu VS, Shah S (2023) White analytical chemistry-driven stability-indicating concomitant chromatographic estimation of thiocolchicoside and aceclofenac using response surface analysis and red, green, and blue model. J Sep Sci 46(11):2300139. https://doi.org/10.1002/jssc.202300139

    Article  CAS  Google Scholar 

  11. Drug data bank of Baclofen, https://go.drugbank.com/drugs/DB00230, Accessed on date 20th Dec 2023

  12. Bali A, Gaur P (2011) A novel method for spectrophotometric determination of pregabalin in pure form and in capsules. Chem Central J 5:1–7. https://doi.org/10.1186/1752-153X-5-59

    Article  CAS  Google Scholar 

  13. Patil DD, Patil MS, Wani YB (2016) Spectrophotometric method for pregabalin determination: an experimental design approach for method development. J Asso Arab Uni Basic Appl Sci 21:31–37. https://doi.org/10.1016/j.jaubas.2015.03.002

    Article  Google Scholar 

  14. Armağan Ö (2009) Development and validation of selective spectrophotometric methods for the determination of pregabalin in pharmaceutical preparation. Chin J Chem 27(4):781–786. https://doi.org/10.1002/cjoc.200990130

  15. Gujral RS, Haque SM, Shanker P (2009) Development and validation of pregabalin in bulk, pharmaceutical formulations and in human urine samples by UV spectrophotometry. Int J Biomed Sci: IJBS 5(2):175

    Article  PubMed  PubMed Central  Google Scholar 

  16. Kasawar GB, Farooqui MN (2010) Development and validation of HPLC method for the determination of pregabalin in capsules. Indian J Pharma Sci 72(4):517. https://doi.org/10.4103/0250-474X.73935

  17. Balaji J, Ramachandra B, Naidu NVS (2014) Analytical RPHPLC method for development and validation of Pregabalin in bulk and the determination of Pregabalin in capsule dosage form. Int J Inno Res Sci Engi Tech J 3(4):11094–11089

    Google Scholar 

  18. Pingale P, Singasane T (2012) Development and validation of HPLC method for the determination of pregabalin in bulk and in pharmaceutical formulations. Res J Pharm Tech 5(6):829–833

    Google Scholar 

  19. Douša M, Gibala P, Lemr K (2010) Liquid chromatographic separation of pregabalin and its possible impurities with fluorescence detection after postcolumn derivatization with o-phtaldialdehyde. J Pharma Biomed Ana 53(3):717–722. https://doi.org/10.1016/j.jpba.2010.04.008

    Article  CAS  Google Scholar 

  20. Mandal U, Sarkar AK, Gowda KV, Agarwal S, Bose A, Bhaumik U, Pal TK (2008) Determination of pregabalin in human plasma using LC-MS-MS. Chromatographia 67:237–243. https://doi.org/10.1365/s10337-007-0440-2

    Article  CAS  Google Scholar 

  21. Vaidya VV, Yetal SM, Roy SM, Gomes NA, Joshi SS (2007) LC-MS–MS Determination of pregabalin in human plasma. Chromatographia 66:925–928. https://doi.org/10.1365/s10337-007-0430-4

    Article  CAS  Google Scholar 

  22. Antunovic M, Dzudovic J, Kilibarda V, Vucinic S, Djordjevic S (2023) Validation of the rapid and simple LC-MS/MS method for the quantification of pregabalin in plasma of acutely poisoned patients. Acta Chromatographica: 1–8. doi:https://doi.org/10.1556/1326.2023.01104

  23. Önal A, Sagirli O (2009) Spectrophotometric and spectrofluorimetric methods for the determination of pregabalin in bulk and pharmaceutical preparation. Spectrochimica Acta Part A: Mol Biomol Spectro 72(1):68–71. https://doi.org/10.1016/j.saa.2008.08.009

    Article  ADS  CAS  Google Scholar 

  24. Shaalan RAA (2010) Spectrofluorimetric and spectrophotometric determination of pregabalin in capsules and urine samples. Int J Biomed Sci:IJBS 6(3):260

    Article  MathSciNet  CAS  PubMed  Google Scholar 

  25. Walash MI, Belal F, El-Enany N, El-Maghrabey MH (2011) Simple and sensitive spectrofluorimetric method for the determination of pregabalin in capsules through derivatization with Fluorescamine. Luminescence 26(5):342–348. https://doi.org/10.1002/bio.1235

    Article  CAS  PubMed  Google Scholar 

  26. Saleh HM, El-Henawee MM, Ragab GH, Mohamed OF (2014) Spectrophotometric and spectrofluorimetric determination of pregabalin via condensation reactions in pure form and in capsules. Int J Pharma Chem Bio Sci 4(3):738–747

    CAS  Google Scholar 

  27. Abdel Hamid MA, Mabrouk MM, Ahmed HM, Samy B, Batakoushy HA (2022) Carbon quantum dots as a sensitive fluorescent probe for quantitation of pregabalin; application to real samples and content uniformity test. Luminescence 37(1):170–176. https://doi.org/10.1002/bio.4158

    Article  CAS  PubMed  Google Scholar 

  28. Derayea SM, Attia TZ, El Nady M (2018) The utility of acetylbutyrolactone for spectrofluorimetric determination of two gamma-aminobutyric acid analogues. J Adv Biomed Pharma Sci 1(1):6–12

    Google Scholar 

Download references

Acknowledgements

The Maliba Pharmacy College’s Principal and the Uka Tarsadia University’s Provost are thanked by the authors for their enormous help in providing the necessary infrastructure and instrumentation equipment to carry out the research endeavor. Their contributions were crucial to the accomplishment of this investigation.

Funding

No funding support from any agency.

Author information

Authors and Affiliations

Authors

Contributions

Dr Pintu Prajapati was involved in drafting, conceptualization, supervision and review. Veera Shakar Pulusu contributed to review, software analysis handling and drafting. Shailesh Shah took part in supervision and review support.

Corresponding author

Correspondence to Pintu Prajapati.

Ethics declarations

Ethics approval and consent to participate

Our research work does not include use of animal and human being. The manuscript has been solely submitted for publication in the Future Journal of Pharmaceutical Sciences. The authors of manuscript have declared that they do not have any conflicts of interest.

Consent for publication

Our research work does not include any human study. The manuscript entitled ‘Design of Experiments and White Analytical Chemistry-driven Green and Sensitive Spectrofluorimetric Estimation of Pregabalin in its Pharmaceutical Dosage Forms and Spiked Human Plasma’ has been solely submitted to Future Journal of Pharmaceutical Sciences.

Competing interests

The authors of the manuscript already declared that they do not have any conflicts of interest for the publication of the manuscript.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Supplementary Information

Additional file 1

. UV spectrum of PGB and fluorescence spectrum of blank.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Prajapati, P., Pulusu, V.S. & Shah, S. Design of experiments and white analytical chemistry-driven green and sensitive spectrofluorimetric estimation of pregabalin in its pharmaceutical dosage forms and spiked human plasma. Futur J Pharm Sci 10, 43 (2024). https://doi.org/10.1186/s43094-024-00615-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s43094-024-00615-3

Keywords